IR2111 ( S ) & (PbF)
Dynamic Electrical Characteristics
V BIAS (V CC , V BS ) = 15V, C L = 1000 pF and T A = 25 ° C unless otherwise specified. The dynamic electrical characteristics
are measured using the test circuit shown in figure 3.
Symbol
Definition
Min. Typ. Max. Units Test Conditions
ton
toff
tr
tf
DT
Turn-on propagation delay
Turn-off propagation delay
Turn-on rise time
Turn-off fall time
Deadtime, LS turn-off to HS turn-on &
550
—
—
—
480
750
150
80
40
650
950
180
130
65
820
ns
V S = 0V
V S = 600V
HS turn-off to LS turn-on
MT
Delay matching, HS & LS turn-on/off
—
30
—
Static Electrical Characteristics
V BIAS (V CC , V BS ) = 15V and T A = 25 ° C unless otherwise specified. The V IN , V TH and I IN parameters are referenced to
COM. The V O and I O parameters are referenced to COM and are applicable to the respective output leads: HO or LO.
Symbol
Definition
Min. Typ. Max. Units Test Conditions
V IH
Logic “1” input voltage for HO & logic “0” for LO
6.4
9.5
12.6
—
—
—
—
—
—
V CC = 10V
V CC = 15V
V CC = 20V
V IL
Logic “0” input voltage for HO & logic “1” for LO
—
—
3.8
V
V CC = 10V
—
—
—
—
6.0
8.3
V CC = 15V
V CC = 20V
V OH
High level output voltage, V BIAS - V O
—
—
100
I O = 0A
V OL
I LK
I QBS
I QCC
I IN+
I IN-
V BSUV+
V BSUV-
V CCUV+
V CCUV-
I O+
Low level output voltage, V O
Offset supply leakage current
Quiescent V BS supply current
Quiescent V CC supply current
Logic “1” input bias current
Logic “0” input bias current
V BS supply undervoltage positive going threshold
V BS supply undervoltage negative going threshold
V CC supply undervoltage positive going threshold
V CC supply undervoltage negative going threshold
Output high short circuit pulsed current
—
—
—
—
—
—
7.6
7.2
7.6
7.2
200
—
—
50
70
30
—
8.6
8.2
8.6
8.2
250
100
50
100
180
50
1.0
9.6
9.2
9.6
9.2
—
mV
μ A
V
I O = 0A
V B = V S = 600V
V IN = 0V or V CC
V IN = 0V or V CC
V IN = V CC
V IN = 0V
V O = 0V, V IN = V CC
mA
PW ≤ 10 μ s
I O-
Output low short circuit pulsed current
420
500
—
V O = 15V, V IN = 0V
PW ≤ 10 μ s
www.irf.com
3